Overview Low Voltage 3p 160A 200A 225A 250A Moulded Case Circuit Breaker MCCBProduct Description Moulded Case Circuit Br
Overview
Basic Info.
Model NO. BYM1-800
Poles Number 3
Type Circuit Breaker
Function Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
Certification ISO9001-2000, CE, CCC
Rated Insulation Voltage 250V
Ambient Temperature -5ºC--+55ºC
Color White+Black
Standard IEC60947-2
Rated Operation Voltage 400/690
Transport Package Carton
Trademark OEM ODM
Origin China
HS Code 853620000
Production Capacity 40000
Product Description

Low Voltage 3p 160A 200A 225A 250A Moulded Case Circuit Breaker MCCBProduct Description

Moulded Case Circuit Breaker MCCB
Standard:
circuit breaker and auxiliaries comply with the following international standard:
1.IEC/EN 60947-1
Low-voltage switchgear and controlgear-part 1: General rules;
2.IEC/EN 60947-2
Low-voltage switchgear and controlgear-part 2: Circuit breakers;
MCCB(Standard use environment for MCCB)
1. Ambient temperature: Within the range of -5ºC--+55ºC(However, when the temperature exceed 40ºC,it should be considered to reduce the capacity to use);
2. Relative humidity: Within the range of 45%--85%;
3. Altitude: 2000m or less(However, if it exceeds 1000m, atmosphere correction through humidity test and withstand voltage test can be considered);
4. Atmosphere where excessive steam, oil steam, smoke, dust, salt and other corrosive materials do not exist;
Classification:
According to the poles: 2-poles, 3-poles
According to the rated current: Fix type

Product Parameters
Thermal-Magnetic fixed type Circuit Breakers
ModelBYM1-800
Breaking Capacity Code MH
Rated Current of Frame size- Inm (A)800A
Rated Current-In(40,50 or 55ºC) (A)630.700.800
Rated İnsulation Voltage -Ui(a.c.) 50-60Hz (V)800V
Rated operation Voltage -Ue(a.c.) 50-60Hz (V) 400/690400400
Number of Pole 343
Rated ultimate short Circuit breaking Capacity kA Icu AC400V/50Hz O-CO (KA) 5086100
Rated service short Circuit breaking Capacity kA Ics AC400V/50Hz O-CO-CO (KA) 203065
Rated short-circuit breaking capacity Icm(peak)/cos ф AC400V/50HZ O-CO (KA) 73.5/0.25110/0.25
Rated impulse withstand Voltage -Uimp (V)8000
Dielectric Propery (V) 3000
lonization distance (mm)≤100/0
Endurance Total Cycles 8000
Electrical Life 1000
Mechanical Life 7000
Over Current trip Thermal and Magnetic release fix type
Category (EN 14048.2/IEC 60947-2)Main circuit A/0
Auxiliary circuit AC-15
Under Voltage Release
Shunt Release
Auxiliary Contact
Alarm Contact
Auxiliary Contact and Alarm Contact
Handle Operation Mechanism
Electrical Operastion Mechanism
Terminal cover
Phase seperator
Extention Handle -
W (mm)3P210
4P280
L (mm)3P280
4P280
H (mm)3P115.5
4P115.5
WeightFixed version 3P/4P1.2/1.6
Plug-in version 3P/4P1.4/1.8
Draw out version 3P/4P-
Detailed Photos

Low Voltage 3p 160A 200A 225A 250A Moulded Case Circuit Breaker MCCB

Low Voltage 3p 160A 200A 225A 250A Moulded Case Circuit Breaker MCCB


Low Voltage 3p 160A 200A 225A 250A Moulded Case Circuit Breaker MCCB

Low Voltage 3p 160A 200A 225A 250A Moulded Case Circuit Breaker MCCB

Low Voltage 3p 160A 200A 225A 250A Moulded Case Circuit Breaker MCCB