Yc9va Single Phase 1
Basic Info.
Model NO. | YC9VA |
Pollution | 3 |
Adjustment of Current | 1A~63A |
Deviation | 2% |
Rated Frequency | 50/60Hz |
Rated Voltage | AC230V |
Transport Package | 100units/CTN |
Specification | YC9VA |
Trademark | CNC or OEM |
Origin | China |
HS Code | 8536300000 |
Production Capacity | 5000000/Month |
Packaging & Delivery
Package Size 47.00cm * 32.00cm * 32.00cm Package Gross Weight 25.000kgProduct Description
Product Description
YC9VA Single Phase Voltage Relay Adjustable Over Under Voltage Protectorwith LED Display
General
YC9VA votage and current display relay is a microprocessor-based voltage monitoring device for single-phase AC networks to protect electrical equipment from surge voltage. The device analyzes the main voltage and displays its current value on a digital indicator. Load is switched by electromagnetic relay. The user can set the current voltage value and delay time through the button. The value is stored in non-volatile memory. Aluminum wires and copper wires can be used for connection.
Application
YC9VA/YC9VA2 voltage and current display relay used in administrative, industrial and residential buildings and has the function of
protecting single-phase lines:
Undervoltage protection;
Overvoltage protection;
Working under voltmeter mode;
Overcurrent proteciton.
Parameter | Data |
Rated power supply voltage | AC230V |
Rated frequency | 50Hz |
Maximum voltage adjustment range | 230V~300V |
Minimum voltage adjustment range | 120V~210V |
Range of adjustment of the maximum current | 1A~63A |
Deviation | 2% |
Maximum action time | <275V: 0,1s, ≥275V: 0,02s |
Delay time adjustment range | 1-90s |
Minimum action time | 0.5s (≥160V); <0.1s(<160V) |
Delay time adjustment range, overcurrent trip time | 1-90s (Inom <Iism <Imax :); 0.1s (Iism≥Imax) |
Voltmeter accuracy | ≤1% |
Rated insulation voltage | 400V |
Output contact | 1NO |
Protection | IP20 |
Pollution | 3 |
Electrical life | 100000 times |
Mechanical life | 1000000 times |
Altitude | ≤2000m |
Operating temperature | -5°C~40°C |
Relative humidity | 50% at 40ºC (non-condensing) |
Storage temperature | -40°C~55°C |
Installation | 35mm DIN rail |
Range of adjustment of the on-delay time | 1-90s |
Operation
When a voltage is applied to the device, the digital indicator will display the current value of the voltage in the network.
A flashing light indicates that there is no voltage on the output of the device. If the supply voltage is within the set range, after Ton
(default is 30 seconds), the load will turn on and the indicator will stop flashing. If the voltage is not within the specified range, the
load will not be connected to the line until the voltage returns to normal. Meantime, if the voltage is lower than the set lower limit
during the restart, the error indicator will flash. If the voltage is higher than the set upper limit, the error indicator will remain on.
Company Profile